OML-ESE/3.3, ESE4.3, ESE5.3, ESE6.3, Early Discharge Arrestor, Pre-Discharge Arrestor, Early Discharge Terminal,...
Product Description:
ESE3.3, ESE4.3, ESE5.3, ESE6.3 series of early discharge lightning rods are mainly used by the exciter to absorb and store energy from the electric field of nature, and the reflector and the tip of the lightning arrester have a good electrical connection with the earth, which is in equipotential state. So usually, there is an electric field strength between the exciter and the transmitter, whenever the lightning flash occurs before the electric field strength will increase rapidly, the potential difference between the exciter and the reactor is roughly equivalent to the potential between the thundercloud and the earth, the rapid increase in the voltage drop between them will cause the tip of the firing, and the air around the tip of the tip of the ionization, the formation of the tip of the discharge phenomenon. The rapid increase in the electric field between the lightning rod's central collecting rod and the exciter causes the air ionization generated by the tip to be discharged in a very short and precise period of time, due to the presence of a large number of ions, thus reducing the natural Corona effect and generating an expected upward discharge channel, which can quickly and safely intercept and safely discharge lightning into the earth.
Functional Features::
- The fastest preemptive discharge time, i.e., prioritizing the lightning into the ground, the protection radius is greatly increased.
- No electronic systems will be damaged by surge impacts.
- Under the same installation height, the protection radius is several times larger than that of ordinary lightning rods.
- Fully active lightning attraction system that activates itself when there is lightning.
- Beautiful appearance, the use of stainless steel materials, can be installed in harsh environments.
- The OML-ESE/F3 ion lightning rod is easy to install: the exciter is insulated from the reflector and the central collecting rod.
typical application::
- Communications base stations
- weather stations
- gas station
- power system
- airfield
- Military systems
Technical Parameters
| name (of a thing) | model number | Early Discharge Time | pinnacle | weights | Number of Needle Wing Tips | base material |
| ESE Early Discharge Lightning Rods | OML-ESE3.3 | 25µs | 663mm | 3.9KG | 9 branches. | 304 stainless steel |
| OML-ESE4.3 | 35µs | 663mm | 5.2KG | 12 sticks. | 304 stainless steel | |
| OML-ESE5.3 | 45µs | 663mm | 6.3KG | Fifteen. | 304 stainless steel | |
| OML-ESE6.3 | 65µs | 663mm | 8.9KG | Eighteen. | 304 stainless steel |
OML-ESE3.3 Lightning rod structure diagram

Lightning rod installation instructions
1, according to the area of the protected building, height, location of the number of days of lightning and geographic environment correction factor, the nature of the use of the building to determine the category of building lightning protection.
2, with lightning protection category and the area of the building, to determine the selection of a lightning rod or several.
3. The lead wire should be electrically connected to the main steel reinforcement of the building, or two or more lead wires (lower conductors) should be made according to the regulations.
4. The lead wires (lower conductors) should be disconnected and insulated on the ground nearby.
5, grounding body, grounding resistance, lightning protection ground network should be in accordance with the requirements of lightning protection standard GB50057-2010.
Omrdon Technology 