OML-SR,Straight Optimized Stainless Steel Lightning Rods,Outdoor Roof Lightning Rods
Product Description:
OMRDON (OMRDON) series straight rod type optimized stainless steel lightning rod, is a non-inductive low impedance metal inner conductor through the lead, the lightning current after the flashover to the earth, so that the protected antenna towers or buildings do not occur side-strike and charged. In most cases the impact of the electrostatic field cable is less than 1/10 of the tower impedance, which avoids the building or tower from being energized and eliminates flashover.
Functional Features::
- Triggered by the electric field principle, it does not have any possible aging electronics inside, thus truly maintenance-free; it is especially suitable for places that cannot be repaired after installation, such as churches and building spires that are often difficult to reach.
- It is made of 304 stainless steel so that it can work normally in chemically polluted places; another bronze material can be used in ancient buildings.
- Lightning rod (flange included), extensions are also available.
- Flexible and versatile, can be customized according to user needs.
typical application
- Communications base stations
- weather stations
- gas station
- repository
- airport
Technical Parameters
| name (of a thing) | Straight rod optimized lightning rod |
| model number | OML-SR |
| lightning current capacity | 300KA |
| Ground resistance requirements | ≤10Ω |
| wind force | ≤40m/s |
| amplitude decay rate | ≥80 |
| high degree | 0.5-30 m (customizable) |
| Main Material | 304 |
Product Installation Diagram

Lightning rod installation instructions
The installation of pre-discharged lightning rods must strictly follow the mandatory provisions of the National Standard of the People's Republic of China - "Code for Lightning Protection Design of Buildings" (GB50057-2010):
1, according to the area of the protected building, height, location of the number of days of lightning and geographic environment correction factor, the nature of the use of the building to determine the building to prevent
Ray Category.
2, by the lightning protection category and the area of the building, to determine the selection of a lightning rod or several.
3. The lead wires shall be electrically connected to the main steel reinforcement of the building, or at least two or more lead wires shall be made according to the regulations.
4. The lead wires should be disconnected and insulated on the ground in the vicinity.
5, grounding body, grounding resistance should be implemented in accordance with the requirements of GB50057-2010.