Tel. +86-755-82591856     E-mail. info@omrdon.com

Shenzhen OMRDON TECHNOLOGY

---- specializes in lightning safety and protection.

OMP-APM100/4 100KA 三相电涌保护器,浪涌抑制器,用于配电房配电柜、配电箱、机房、基站设备箱 - 欧姆雷盾omrdon Technology

Low-voltage power line lightning protection/

OMP-APM100/4 100KA three-phase surge protector, surge suppressor, for power distribution cabinets, distribution boxes, equipment rooms, base station equipment box

Name.Class I Power Surge Protector

Model.OMP-APM100

Nominal discharge current.60KA

最大放电电流:100KA

Voltage protection level.≤2.8KV

Response time.≤25ns

Temperature range.-40°C...+85°C

Dimensions.144mmx90mmx68mm

Housing material.Reinforced flame retardant PBT

Protection level.IP20

  • 产品详情
  • Inquiry

OMP-APM100/2,OMP-APM100/1+NPE,OMP-APM100/4,OMP-APM100/3+NPE,100KA single-phase/three-phase surge protector,surge suppressor for power distribution cabinets,distribution boxes,equipment rooms,base station equipment box

Product Description:

         OMRDON surge protector (Surge Protection Device, referred to as SPD) (also known as power supply lightning protector, power supply lightning arrester, surge protector, overvoltage protector), the basis of its design in line with the GB18802.1, IEC61643-1 technical standards; applicable to AC 380V (50Hz/60Hz) and the following TN-S, TN-C-S, TT, IT and other power supply line system of lightning electromagnetic pulse (LEMP) protection, for lightning strike area of the LPZOA zone or LPZOB zone and LPZ1 zone interface.

The product adopts rail type flame retardant shell package, built-in high quality high-speed over-voltage protection devices, the power line induction of lightning high-voltage pulse has a highly efficient protection and defense function.

Functional Features:

  • Optional telecommunication terminal alarm function, easy to remote alarm monitoring
  • Withstand up to 100KA (8/20μs) lightning current shock.
  • Fast reaction speed, action response time is less than 25ns.
  • Flame retardant housing designed for easy installation on 35mm electrical rails.
  • Built-in thermal release failure disengagement device, so that the protector can be automatically disconnected when it fails due to overheating or breakdown.
  • The visual alarm window color indicates the working status of the protection, green (normal), red (fault).
  • Reinforced flame retardant PBT housing

typical application

  • Low-voltage household switchgear
  • Floor distribution box
  • Main distribution box for machine room
  • Outdoor equipment box
  • communications base station
  • PLC control cabinet

Technical Parameters

name (of a thing)

 T2 Power Surge Protector

model number

OMP-APM100/4

OMP-APM100/NPE

item number

800106

800107

protected mode

L-N, L-PE, N-PE

 N-PE

Rated Working Voltage

220/380V

Maximum continuous operating voltage (Uc)

385V50H/60Hz

255V50H/60Hz

Nominal discharge current (In) (8/20μs)

60kA (8/20μs)

125kA (8/20μs)

Maximum discharge current (Imax)(8/20μs)

100kA (8/20μs)

--

Lightning impulse current (Iimp)

--

50KA (10/350μs)

Voltage protection level Up (8/20μs)

≤2.8KV

≤2.0KV

response time

≤25 ns

≤100 ns

Size

144×90×68mm

Backup Protector Selection

D type 63~125A

Connection wire cross-section (L/N)

≥ 16mm2

Connection to the grounding wire cross section (PE)

≥ 25mm2

working environment

-40℃~+ 85℃

relative humidity

≤95

Installation

35mm standard electrical rail

Housing Material

Reinforced Flame Retardant Plastic (V0)

Test basis

GB/T 18802. 11, IEC 61643-11

 

 
 

Product Dimension Drawing

Installation Precautions

1, surge protectors installed in parallel in the line, and remember.

2. Do not connect the line in reverse or wrong.

3, surge protector installed in the front of the protected equipment the closer the better.

4. The equipment needs to be inspected regularly, and the product must be replaced immediately after deterioration.

5. Remember not to work with electricity.

    personstradedistributor