OMP-ASA20/220-EO 20KA Composite Series Power Surge Protector (Surge Suppressor) 220V/120V/48V/24V/12V, no leakage current, low residual voltage, especially suitable for surge protection of terminal equipment.
Product Description:
OMRDON composite series-connected power surge protector (SPD) is a high-performance surge protection device designed for AC/DC power distribution system. Applicable to program-controlled switches, security monitoring, broadcasting systems, communications equipment, fire systems, industrial control systems and other scenarios, can effectively defend against overvoltage and overcurrent caused by lightning strikes and power grid surges, to protect the long-term stable operation of equipment. Compact structure, easy to install, suitable for all kinds of harsh environments, is the preferred solution for lightning protection of terminal equipment.
This series of lightning protection adopts composite balanced protection circuit, with differential mode (line to line) and common mode (line to ground) full-mode protection capability, low residual voltage, fast response (≤ 25ns), especially suitable for frequent lightning activity, voltage fluctuation sensitive outdoor or industrial places. The housing is made of aluminum alloy, supports optional 35mm rail mounting, and is equipped with LED status indicator to show the operation status of the lightning protector in real time.
Functional Features::
- High tolerance:Maximum discharge current 20KA (8/20μs), reliable against strong surge impacts
- Full mold protection:Differential mode + common mode dual protection, covering the entire path of line to line and line to ground
- Rapid Response:Response time ≤ 25 nanoseconds, rapid suppression of power surges
- No leakage current design:Stable performance and long service life
- Status visualization:Green LED indicator, positive often light, failure off, easy maintenance
typical application::
- Communications base stations and programmed switches
- Security Surveillance Systems & Video Equipment
- Background broadcasting and audio/video system
- Fire alarm and control equipment
- Industrial automation and PLC control systems
- DC power equipment (e.g., solar control, DC panels, etc.)
Technical Parameters
Functional parameters
| model number | OMP-ASA20/220-EO |
| SPD category | flammable |
| test level | T2(II), T3(III) |
| Nominal operating voltage (L-N) (Un) | 220 Vac |
| Maximum Continuous Operating Voltage (UC) | 320 Vac |
| T2 Nominal inrush current (In) | 10KA (8/20μs) |
| T2 Maximum inrush current (Imax) | 20KA (8/20μs) |
| T3 Impulse withstand voltage (Uoc) | 20KV (1.2/50μs) |
| Voltage Protection Rating (VPR) @ 10KA (8/20μs) | ≤1.1K V |
| Voltage Protection Rating (VPR) @ 7.5KA (8/20μs) | ≤900 V |
| Voltage Protection Rating (VPR) @ 3KA (8/20μs) | ≤700 V |
| Response time (Ta) | 25ns |
| Load Current (IL) | 5A/10A |
| Leakage Current (LC) | ≤0μA |
| protected mode | l-n, l-pe, n-pe |
| failure indication | LED indicator (green: normal, off: disabled) |
(old) cunningparameters
| Wiring Method | wiring terminal |
| Maximum wire diameter | ≤4mm2 (12AWG) |
| Housing Material | aluminum |
| sizes | 95*75*57mm |
| weights | 130g [0.286 Ibs] |
Environmental norms
| Temperature operating range | -40 ~ +85℃, altitude ≤4kM |
| Environmental humidity | 30%~90% |
| Enclosure protection class (IP) | IP20 |
Other information
| Test Standards | gb/t18802.11 / iec61643-11 |
| Order No. | 800184 |
Series Model Information

Simulated Lightning Impact Test








Product Dimension Drawing

Installation Notes:
● Wired correctly:Input (IN) is connected to the power supply side, and output (OUT) is connected to the device side; reverse connection is strictly prohibited.
● Installation near you:Get as close as possible to the front of the protected equipment for better protection.
● Reliable grounding:Grounding resistance ≤ 4Ω, grounding wire cross-sectional area ≥ 2.5mm².
● Operation with electricity is prohibited:Installation and replacement must be done without power.
● Regular inspections:It is recommended that inspections be carried out at least once a year, and indicator lights found to be abnormal should be replaced in a timely manner.
Omrdon Technology 