Tel. +86-755-82591856     E-mail. info@omrdon.com

Shenzhen OMRDON TECHNOLOGY

---- specializes in lightning safety and protection.

OMP-ASP20550-HELV,超薄7mm,220Vac, Uc550V, 20KA, 20KV,交流/直流,导轨式高能低残压电源防雷器,接线免拧螺丝 - 欧姆雷盾omrdon Technology

Low-voltage power line lightning protection/

OMP-ASP20550-HELV,Ultra-thin 7mm, 220Vac, Uc550V, 20KA, 20KV, AC/DC, DIN-Rail High Energy Low Residual Voltage Power Surge Protector, Screwless Wiring

model number

OMP-ASP20550-HELV

test level

T2,T3

Nominal operating voltage (Un)

220 Vac

Maximum Continuous Operating Voltage (UC)

550 Vac

T3 Impulse withstand voltage (Uoc)

20KV (1.2/50μs)

T2 Nominal inrush current (In)

10KA (8/20μs)

T2 Maximum inrush current (Imax)

20KA (8/20μs)

Voltage Protection Rating (VPR)

≤900 V@10KA (8/20μs)

Nominal Current (IL)

10A

protected mode

l-n, l-pe, n-pe

Wiring Method

Inline Cage Terminals

sizes

7*64*93mm

  • 产品详情
  • Inquiry

OMP-ASP20550-HELV,Ultra-thin Case 7mm,220Vac,Uc550V,20KA,20KV,AC/DC,DIN-Rail High Energy Low Residual Voltage Power Surge Protectors,Screwless Wiring

Product Description:

         OMRDON OMP-ASP20550-HELV series power surge protector (SPD, surge suppressor, surge protector) is designed for 7mm ultra-thin shell, does not occupy the installation space, using direct insertion cage terminal, wiring is very convenient, no need to screw in screws, and can be utilized to ground the rail, saving installation time.

This series of products are mainly applied to AC/DC terminal equipment power supply system, the product adopts the patented technology design, with high UC and low residual voltage, especially suitable for installation in the grid voltage fluctuation, easy to be struck by lightning at the site equipment.

High Uc: means that the protector can withstand higher voltage fluctuations without false operation;
Low Residual Pressure: This means that the end equipment will be subjected to lower residual pressure shocks, prolonging the life of the equipment.

Functional Features::

  • High UC and low residual voltage, the use of patented technology to effectively solve the use of unstable grid voltage, fluctuations in the use of the scene, not only has a high continuous operating voltage, but also has a low residual voltage, effective protection of field equipment.
  • Maximum surge inrush current 20KA.
  • 7mm ultra-thin case that doesn't take up much space.
  • Plugs directly into cage terminals without screwing.
  • Can be grounded directly using the rail.
  • Multiple operating voltage options: AC220V, AC110V, DC48V, DC36V, AC/DC24, DC12V.

typical application

  • communications base station
  • PLC control system
  • Security Video Surveillance System
  • Fire Alarm System
  • Perimeter Alarm
  • Temperature and humidity acquisition equipment

Technical Parameters::

electronicparameters

model numberOMP-ASP20550-HELV
test levelT2,T3
Nominal operating voltage (L-N) (Un)220 Vac
Maximum Continuous Operating Voltage (UC)550 Vac
T3 Impulse withstand voltage (Uoc)20KV (1.2/50μs)
T2 Nominal inrush current (In)10KA (8/20μs)
T2 Maximum inrush current (Imax)20KA (8/20μs)
Voltage Protection Rating (VPR) @ 20KA (8/20μs)≤900 V
Voltage Protection Rating (VPR) @ 10KA (8/20μs)≤800 V
Voltage Protection Rating (VPR) @ 3KA (8/20μs)≤700 V
Response time (Ta)25ns
Load Current (IL)10A
protected model-n, l-pe, n-pe

(old) cunningparameters

Wiring MethodInline Cage Terminals
Housing MaterialPA66 UL94-V0
Grounding methodDIN rail/terminal
Maximum wire diameter4mm2 /12AWG
sizes7*64*93mm
weights130g [0.28 Ibs]

Environmental norms

Temperature operating range-40 ~ +85℃,Altitude≤4km
Environmental humidity30%~90%
Enclosure protection class (IP)IP20

Other information

Compliance CertificationCE, RoHs, ISO9001-2015
Test Standardsgb/t18802.11 / iec61643-11
Order No.8001846

Series Model Information

Simulated Lightning Impact Test

Dimensional drawings and installation diagrams

 

    personstradedistributor

    下一篇:

    在线留言

    这个站点使用 Akismet 来减少垃圾评论。了解你的评论数据如何被处理