OMS-DIN/3850, 380-512 MHz, 1/4 wave antenna, lightning arrester.DC Block.3000W, 50kA., High Power RF Broadcast/Radar Antenna Surge Protector
Product Description:
OMRDON OMS-DIN/3850 RF coaxial antenna lightning protector (SPD, surge protector) is the use of 1/4 wavelength-type short-circuit rod filtering principle, which is widely used in the 380-512MHz band relatively fixed radio equipment, its main advantages are lightning protection effect is obvious, the impact of the current withstand is particularly large (50KA), the insertion of the signal is small loss. λ /4 high-frequency coaxial lightning protection can also greatly inhibit the interference of different frequencies; these features are related to its unique principle and structure. Suitable for satellite wireless communications mobile base stations, microwave communications, radio and television coaxial antenna feeder system signal surge protection is installed in the lightning protection zoning LPZ 0 A-1 and subsequent zoning.
Functional Features::
- Lightning impulse current up to 50KA
- Maximum output power 3KW
- Frequency range 380-512MHz
- DC Block
- N-type connector with one male and one female (female to male)
- Very low VSWR <1.12
- International Certification RoHS, CE, FCC
typical application::
- UHF
- radar station
- Emergency response system
- Public safety systems
- microwave station
Technical Parameters::
| model number | OMS-DIN/3850 |
| Nominal discharge current (In) | 25 KA (8/20μs) |
| Rated Inrush Current (Ism) | 50 KA (8/20μs) |
| Voltage protection level (Up) | ≤15V |
| Reaction time (Ta) | ≤1ns |
| Maximum transmission power | 3KWatts |
| VSWR | ≤1.12 |
| characteristic impedance | 50Ω |
| insertion loss | ≤0.1 dB |
| frequency range | 380-512MHZ |
| Insulation impedance | ≥5000 MΩ |
| Connector Type | 7/16DIN@Female to Male (L29) |
| Housing Material | Brass @ Ternary Alloy (Customizable) |
| Ground resistance and wire diameter | ≤4Ω /≥4mm2 |
| sizes | 65.6*77.3mm |
| Operating Temperature Range | -40 ~ +85°C, Altitude ≤ 4km |
| Relative air humidity | 30%~90% |
| Protection class (IP) | IP67 |
| Compliance Certification | CE, RoHs, ISO9001-2015 |
| Implementation standards | gb18802.21/lec61643-21/iec60169-4 |
| item number | 8004211 |
Typical Performance Test Data::


Simulated Lightning Impact Test::


Product Dimension Drawing::

Installation Notes:
- This series of lightning protectors does not distinguish between input and output terminals, any port can be connected to the protected equipment;
- The closer the lightning protector is mounted to the front of the protected equipment, the better the result;
- The equipment needs to be inspected regularly and the product must be replaced immediately after deterioration;
- Grounding must be good, and it is recommended that the grounding resistance be no greater than 4 ohms.
Omrdon Technology 