Tel. +86-755-82591856     E-mail. info@omrdon.com

Shenzhen OMRDON TECHNOLOGY

---- specializes in lightning safety and protection.

OMS-N-SMA/KK/3.0,20KA,DC-3.0GHz,N转SMA同轴天馈避雷器(馈线防雷器、基站天线避雷器),DC-Pass - 欧姆雷盾omrdon Technology

Coaxial RF Surge Protector/

OMS-N-SMA/KK/3.0,20KA,DC-3.0GHz,N to SMA coaxial antenna lightning arrester (feeder lightning arrester, base station antenna lightning arrester),DC-Pass

Name:Antenna Feeder Surge Protectors

Model.oms-n-sma/kk/3.0

Nominal discharge current.10KA

最大放电电流:20KA

DC breakdown voltage:90V/230V/350V/600V (optional)

Maximum RF power:150W

Characteristic impedance:50Ω

VSWR.≤1.2

Insertion Loss.≤0.2db

Frequency range.DC-3.0 GHz

Order number:8004391

  • 产品详情
  • Installation Legend
  • Frequently Asked Questions (FAQ)
  • Inquiry

OMS-N-SMA/KK/3.0,20KA,DC-3.0GHz,DC-Pass,N to SMA Coaxial Antenna Lightning Arrester (Feeder Lightning Arrester, Base Station Antenna Lightning Arrester)

Products::

OMRDON OMS-N-SMA/KK/3.0 , N to SMA Antenna Surge Protector is a high-performance surge protector (SPD) designed for modern wireless communication systems. The product provides reliable protection against induced lightning strikes for all types of RF signal transmission paths, effectively suppresses surge overvoltage introduced by the feeder, and guarantees the safe and stable operation of the antenna and back-end sensitive equipment.

This lightning protector adopts GDT protection technology and low-loss design, providing strong lightning discharge capacity (maximum 20KA) while ensuring excellent signal transmission quality, the working band covers 0-3.0GHz, and it can be widely used in 5G base stations, satellite communications, microwave transmission, wireless monitoring and all kinds of fixed/mobile communication base stations. The product complies with GB/T18802.21 and IEC61643-21 lightning protection standards, with IP67 protection level and wide temperature operating characteristics, it is the ideal choice to build a complete lightning protection zoning system from LPZ0A-1 to the front end of the equipment.

Functional Features::

  • High lightning current capabilityMaximum discharge current up to 20KA (8/20μs), reliably discharging the lightning current.
  • Wide bandwidth and low lossSupport 0-3.0GHz frequency range, VSWR ≤1.2, insertion loss ≤0.2dB, to ensure the quality of signal transmission.
  • Fully sealed waterproof design: Enclosure protection class IP67, adapted to harsh outdoor environments.
  • Multiple interfaces availableN型连接器:Standard N-type connector to SMA@KK female/female ( female to female)
  • DC-capable:: DC-Pass
  • international certification  RoHS, CE, FCC

typical application::

  • Mobile communication base stations (4G/5G, SCT, CDMA, PHS)
  • Satellite receiving stations, microwave links
  • Wireless Monitoring Transmission System
  • Radar and GPS navigation base stations
  • Radio and television signal towers

Technical Parameters

model numberoms-n-sma/kk/3.0
Nominal discharge current (In)10 KA (8/20μs)
Maximum discharge current (Imax)20 KA (8/20μs)
Reaction time (Ta)≤100 ns
Maximum transmission power Pt150 Watts
VSWR≤1.2 
DC breakdown voltage (100V/s)90/230/350/600 Volts
Maximum pulse voltage (1KV/μs)650/700/750/800 Volts
characteristic impedance50Ω
insertion loss≤0.2 dB
frequency rangeDC-3.0 GHz
Insulation impedance≥1GΩ
interface methodN to SMA@KK (Femaleto Female)
Housing MaterialBrass@Nickel Plated/Ternary Alloy
Ground resistance and wire diameter≤4Ω /≥4mm2
sizes55*21.5mm
Operating Temperature Range-40 ~ +85℃,altitude ≤4km
Relative air humidity30%~90%
Protection class (IP)IP67
Compliance CertificationCE, RoHs,FCC,IP67,ISO9001-2015
Implementation standardsgb18802.21/lec61643-21/iec60169-4/iec60068-2-52
item number8004391

Typical Performance Test Data

Simulated Lightning Impact Test

Product Dimension Drawing

Installation Diagram Reference

Installation and Maintenance Guide Installation Recommendations

1. In order to strengthen the lightning protection effect, it is recommended to connect an antenna lightning protector in series with each of the antenna outputs and equipment inputs.

2. The grounding wire should be as short as possible, with a cross-sectional area of not less than 4mm² and a grounding resistance of not more than 4Ω, and ensure a reliable connection with the lightning protection grounding bus.

3. Although this product is IP67 rated, it is recommended that it be protected from rain when installed outdoors to avoid prolonged rain intrusion.

Maintenance Description.

● This product is a maintenance-free type of lightning protector. If an abnormality occurs in the communication system, the lightning protector can be temporarily removed for testing;

●If the system returns to normal, it means that the lightning arrester has been damaged, so please replace it promptly.

 

 

📌 I. Installation and wiring class

Q1: Where should I install a lightning protector?
A:It is recommended that theantenna outputrespond in singingReceiver equipment inputAn antenna lightning protector is installed in each case to form two levels of protection to maximize the suppression of induced lightning overvoltage.

Q2: What are the requirements for a grounding wire?
A:The grounding wire shouldAs short and straight as possibleThe cross-sectional area is not less than 4mm²The grounding resistance is recommended to be ≤4Ω, and ensure reliable connection with the lightning protection grounding row or grounding bus to avoid coiling of the grounding wire or too long to affect the effect of current drain.

Q3: What do I need to pay attention to for outdoor installation?
A:This product has IP67 Protection RatingThe product can be adapted to outdoor environments, but it is still recommended to take measures to protect it from rain and avoid prolonged direct rain or immersion.


📡 II. Performance and Parameter Classes

Q4: Does the lightning protector affect signal transmission?
A:Under normal circumstances, this productInsertion loss ≤0.2dBThe VSWR ≤1.2 has minimal impact on signal transmission and does not affect communication quality.

Q5: What frequency ranges are supported?
A:The applicable frequency range is 0-3.0 GHzIt is widely used in most wireless communication systems, including 5G, satellite, microwave, surveillance and other signal transmission.

Q6: What is the response time? Is there any delay?
A:Response time ≤25ns, belonging toRapid ResponseLightning protectors that can operate at the moment of lightning current intrusion without affecting the normal operation of the equipment.


🔧 III. Troubleshooting and Maintenance Category

Q7:How to determine whether the lightning protector is damaged?
A:If there is an interruption in the communication system or an abnormal signal, try toTemporary removal of lightning protectorsConnect the line directly; if the system returns to normal, the lightning protector may have failed and replacement is recommended.

Q8: Do lightning protectors need to be replaced periodically?
A:This product belongs toMaintenance-freeThere is no requirement for periodic replacement. However, after being struck by lightning or used for a long period of time, it is recommended that its grounding status and appearance and communication performance be checked periodically for integrity.

Q9: Can this lightning protector be reused after one lightning strike?
A:This product isSwitching SPDIf the lightning strike action will be automatically restored after withstanding the rated range of surge can continue to use; but if suffered many frequent lightning strikes, available special instruments (such as: lightning protection components tester) to test the lightning protector within the conductor core - shielded shell of the breakdown voltage between the normal, such as the normal is no need to replace.


📦 Fourth, the purchase and application of the class

Q10: Are other interface types supported?
A:Standard connector models are N-Type to SMA (50Ω)If you need other interfaces (e.g. DIN/L29, L27, SMA, TNC, BNC, etc.), we have them available and you can contact our sales staff.

Q11: What communication systems are applicable?
A:Suitable for mobile base station, satellite reception, microwave relay, wireless monitoring, GPS/CDMA/PHS base station, radar system and other RF transceiver scenarios.

Q12:Are there any matching mounting accessories?
A:The standard package does not include mounting bracket or grounding wire, if the user needs, can be added to the configuration, please contact the sales staff to explain the situation.


🛠 V. Technical Support and Warranty

Q13:Does the product have a warranty?
A:Provide free36 Months Warranty, calculated from the date of purchase. Problems caused by human damage or abnormal use are not covered by the warranty.

Q14: Can you provide installation instruction or technical support?
A:Basic installation guides and wiring instructions are available, as well as remote phone/video instruction for installation. For on-site technical support or training, please contact customer service to arrange.

Q15: How can I order or get information?
A:Manuals can be downloaded from the product page on the official website, or you can call/contact the sales department online directly and provide the order number/model number for ordering.


If you have questions not covered above, feel free to contact ourTechnical Support TeamWe will be happy to provide you with professional answers and services.

    personstradedistributor

    Prev:

    下一篇:

    在线留言

    这个站点使用 Akismet 来减少垃圾评论。了解你的评论数据如何被处理