Product ModelOMS-RJ45/4S-ISO
SPD categoryflammable
Test levelC2, B2
Rated operating voltage (Un)5V
Maximum continuous operating voltage (Uc)8V
C2 nominal discharge current (In)5KA (8/20μs)
C2 total discharge current (ITotal) Xassemble-C10KA (8/20μs)
B2 Maximum impulse withstand voltage (Uoc) Xassemble-C6KV (10/700μs)
Voltage protection level (Up) X-X≤15V
Isolated Voltage1.5KV
Maximum data transfer rate100Mbps

  • 产品详情
  • Frequently Asked Questions (FAQ)
  • Inquiry

OMS-RJ45/4S-ISO CAT5 隔离型百兆网络防雷器,用于网络交换机、路由器、工业以太网等网络通信链路的电涌保护

Product Overview

欧姆雷盾(OMRDON)OMS-RJ45/4S-ISO隔离型网络电涌保护器(SPD)是一款专为百兆以太网(10/100Mbps)设计的高性能防雷设备。严格遵循IEC与GB标准,适用于雷击保护区的1-2区与2-3区交界处,有效防御雷电感应、电网波动、静电放电及负载冲击对敏感网络设备的损害。其独特的隔离设计,在提供强大电涌保护的同时,保障信号高速、无损传输,是数据中心、企业网络、通信系统等关键场景的理想防护解决方案。

Functional Features:

✅ Dual protection mechanism

  • Two-stage series composite protection: Low residual pressure and long life provide consistent protection.
  • Triple protection for over-current, over-voltage and clamping: Extremely fast response (≤1ns), instantaneous suppression of surge impacts.

✅ High-speed network compatibility

  • 支持100Mbps百兆传输,插入损耗≤0.2dB,不影响网络速度与稳定性。
  • Isolation voltage up to 1.5KVIt effectively isolates interfering signals and improves transmission quality.

✅ High reliability design

  • Nominal discharge current 5KA, maximum through-current capacity 10KA (8/20μs), high protection capability.
  • Aluminum alloy atomized shielding shell, good anti-interference, support screw fixing or rail mounting, flexible installation.

✅ Plug-and-play, no impact on operation

  • No need to power down the equipment during surge protection, business continues to run for seamless protection.

 Typical Applications:

  • Enterprise local area network (LAN), data center, server room network equipment
  • Interface protection for network switches, routers, servers, firewalls, etc.
  • Network communication links for monitoring systems, intelligent buildings, industrial Ethernet, etc.
  • Outdoor network equipment for communication base stations, radio and television transmission systems, etc.

Technical Parameters

Product ModelOMS-RJ45/4S-ISO
SPD categoryflammable
Test levelC2, B2
Rated operating voltage (Un)5V
Maximum continuous operating voltage (Uc)8V
C2 nominal discharge current (In)5KA (8/20μs)
C2 total discharge current (ITotal) Xassemble-C10KA (8/20μs)
B2 Maximum impulse withstand voltage (Uoc) Xassemble-C6KV (10/700μs)
Voltage protection level (Up) X-X≤15V
Isolated Voltage1.5KV
Maximum data transfer rate100Mbps
Insertion loss (Ae)≤0.2dB
Response time (Ta)≤1ns
Interface TypeRJ45
protected modeX-X, X-C
Number of protected interfacessingle-circuit
Protection Pin1/2,3/6
Connection to grounding wire cross section (PE)≥2.5mm²
InstallationTandem, screw mounted (optional 35mm DIN rail)
working environment-40 to +70°C
relative humidity≤95% (25-30°C)
Enclosure protection levelIP20
Housing Materialaluminum
Test basisgb/t18802.21, iec61643-21

Product Dimension Drawing

Installation and Wiring Guide

1. Installation location recommendations

  • Deployed in series on protected equipmentRecent front-endThe signal path: Signal source (surge) → SPD input (IN) → SPD output (OUT) → protected equipment.
  • Be sure to connect the wires according to the “IN” and “OUT” signs, and do not reverse the connection.

2. Grounding requirements

  • Grounding wire cross section ≥ 2.5mm², grounding resistance ≤ 4Ω.
  • The PE terminal must be equipotentially connected to the lightning protection ground or the equipment enclosure.

3. Maintenance tips

  • No special maintenance is required, and it can be viewed in conjunction with routine system checks.
  • If you find the network abnormal, try to remove the SPD temporarily, if it returns to normal then the SPD may be deteriorated and need to be replaced.

🔧 Product Functionality and Technology Category

Q1: What is the difference between an isolated network surge protector and an ordinary network lightning protector?
A: Isolated SPD adds 1.5KV electrical isolation function on the basis of traditional lightning protection, which can not only resist surge impact, but also isolate ground loop interference, potential difference interference, etc. It is more suitable for long-distance, cross-construction, multi-device interconnection network environment, and significantly improves signal purity and transmission stability.

Q2:这款产品是否支持千兆以上的网络速度?
A:目前此型号专为10/100Mbps以太网设计,暂不支持1G及以上速率。如有更高速率需求,请联系我们的销售人员,我们有另外一款产品支持1000Mbps及以上速率。

Q3:What is the meaning of “voltage protection level ≤15V”?
A: This means that after the surge impact passes through the protector, the residual voltage is limited to 15V or less, which is much lower than the general tolerance value of the network equipment, ensuring the safety of the back-end equipment.

Q4: Does the product require external power supply?
A: Not required. The protector is passive and no additional power supply is required to protect the device.


📦 Installation and Use Classes

Q5: What are some common mistakes to avoid when installing?
A: The most common errors include: input and output are reversed, the ground wire is too long or poorly grounded, and homemade network patch cables are not wired according to the corresponding pins. Please be sure to install it as shown in the manual and make sure the grounding resistance is ≤4Ω.

Q6: Can one protector protect multiple network devices?
A: This model is single RJ45 interface, one-to-one protection. If you need to protect multiple devices, you can use the multi-port model or with rack-mounted centralized protection unit, currently we have 8-way, 16-way, 24-way.

Q7: Can it be installed outdoors or in a humid environment?
A: This product is IP20 rated and is suitable for indoor use or in cabinets/equipment boxes. For outdoor use, please select the outdoor model with higher protection level (e.g. IP65) or add a waterproof case/box.

Q8: Is the indicator light normal? How can I tell if the product is working?
A: This model is designed without indicator light, and the transparent working condition does not affect the signal. If the network link is abnormal/packet loss, you can short-circuit troubleshooting method to determine: if the network is restored after removing the SPD, the SPD may have been deteriorated.


🛡️ Troubleshooting and Maintenance Category

Q9: Will the network be completely interrupted when the lightning protector is damaged?
A: It will. If the signal is interrupted, please check it in time, the lightning protection function may have failed and should be replaced in time.

Q10:How can I tell if the lightning protector needs to be replaced?
A: Regularly check the grounding status and appearance for any abnormality; if encountered after a lightning strike or major surge event, it is recommended to test the protection performance; daily, if the network BER increases and speed decreases, you can also check the status of the SPD.

Q11: What is the typical product lifespan?
A: Lightning protection belongs to the “expendable” protective devices, its life depends on the environment of the frequency and intensity of surge events, and there is no fixed replacement age.

We recommend:

1) IntegrationRoutine inspection before the annual thunderstorm season.;

2) DiscoveryInternet connection anomaly.;

3) The equipment or system is inAnomalies after thunderstorms.

Any of these conditions should be inspected and considered for replacement.


📞 Service and Support Category

Q12: What is the difference between a one-year warranty and a three-year warranty?
A:We will directly replace the new product if there is any non-man-made quality problem within one year; we will provide free maintenance service within the 2nd-3rd year; we will still provide lifelong paid maintenance after three years.

Q13: Do you provide installation instruction or on-site service?
A: We provide free remote installation guidance with graphic/video tutorials. For large projects or contracted partners, on-site support by technicians can be negotiated.

 

If there are any other issues not covered, please feel free to contact us through our 7×24 hour service hotline or online customer service, we will provide you with professional answers.

    personstradedistributor

    Prev:

    下一篇:

    在线留言

    这个站点使用 Akismet 来减少垃圾评论。了解你的评论数据如何被处理